Porosity Determination in CFRP by means of X-ray Computed Tomography Methods
Publication, 2018
Outline
B. Plank, C. Gusenbauer, S. Senck, H. Höller, J. Kastner - Porosity Determination in CFRP by means of X-ray Computed Tomography Methods - Proceedings of the 12th European Conference on Non-destructive Testing, Göteborg, Sweden, 2018, pp. 1-2
Abstract
This contribution deals with material- and X-ray computed tomography (XCT)
parameters influencing the quantitative evaluation of porosity in carbon fibre reinforced
polymer specimens (CFRPs). Different types of CFRPs with porosity were investigated.
High resolution XCT scans were used as reference. Porosity values gained with XCT
methods are compared with ultrasonic testing, acid digestion or materialography.